by Dr Susanne van der Veen.
Gait analysis on a treadmill can provide data with a high resolution over a large number of repeated steps. Commercially available treadmills often incorporate force plates, which allow for the identification of steps based on excursion of the centre of pressure (CoP). Previous studies suggest that CoP gait event detection corresponds well with kinematic-derived detection of the same events, at least during steady-state gait in healthy people. However, the accuracy of gait event detection during enforced gait patterns and pathological gait has not yet been tested. To address this caveat, we validated gait event detection on a single force-plate embedded treadmill with the ability to project targets on the belt to elicit altered gait patterns. And, with the help of my Ph.D. supervisors and a very helpful reviewing process this resulted in my first ‘first’ author paper.
We collected gait data of young healthy adults and stroke survivors during target stepping on the C-Mill treadmill (MotekForcelink, Culenborg, The Netherlands). Gait events were detected using one kinetic and two kinematic methods: 1) vertices of centre of pressure (CoP) cyclograms, 2) vertical velocity and position of the heel marker, and 3) anterior velocity and position of the heel and toe markers. A comparison of these methods revealed that centre of pressure-based gait event detection was most accurate. The kinematic method 2 (vertical velocity of the heel marker) was unsuccessful in 20% and method 3 (anterior velocity of the heel marker) was unsuccessful in 7% when compared to method 1 (CoP based). Both kinematic algorithms detected gait events significantly earlier compared to CoP gait event detection, which can be explained by the fact that the foot is placed on the surface before it is actually loaded. In addition, the high percentage of gait events which were missed by kinematic methods suggest that CoP gait event detection may be more appropriate for altered gait patterns.
Traditionally, gait event detection is applied during steady-state walking. Because of the importance of both accurate detection of gait events in pathological gait and when adapting steps in response to environmental cues, we compared the performance of gait event detection methods during targeted stepping. Based on the results, we conclude that gait event detection can be done more accurately in pathological (paretic) gait as well as in adapted gait patterns (walking to enforced walking patterns) using a CoP-based gait event detection. Our findings suggest that treadmills with embedded force plates (like the C-Mill) can be readily implemented for gait analysis in research and clinical practice to allow for a wide variety of automated gait training.
Publication
van der Veen, S. M., Hammerbeck, U., Baker, R. J., & Hollands, K. L. (2018). Validation of gait event detection by centre of pressure during target stepping in healthy and paretic gait. Journal of Biomechanics. https://doi.org/10.1016/J.JBIOMECH.2018.07.039
About the Author
Susanne van der Veen, Ph.D
Postdoctoral Fellow at the Department of Physical Therapy, College of Health Professions, Virginia Commonwealth University
Copyright
© 2018 by the author. Except as otherwise noted, the ISPGR blog, including its text and figures, is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License. To view a copy of this license, visit https://creativecommons.org/licenses/by-sa/4.0/legalcode.
ISPGR blog (ISSN 2561-4703)
Are you interested in writing a blog post for the ISPGR website? If so, please email the ISGPR Secretariat with the following information:
- First and Last Name
- Institution/Affiliation
- Paper you will be referencing